O2-CO2 Transport and Exchange
Model was written in NetLogo 6.0.2
•
Viewed 493 times
•
Downloaded 22 times
•
Run 0 times
Do you have questions or comments about this model? Ask them here! (You'll first need to log in.)
Info tab cannot be displayed because of an encoding error
Comments and Questions
Please start the discussion about this model!
(You'll first need to log in.)
Click to Run Model
to setup ca if (Scenario = "Normal") ;; setting parameters for different scenarios [ set F-slider 1.0 set PS-O_1-slider 0.2 set PS-O_2-slider 0.012 set PS-alv-slider 0.2 set PS-C_1-slider 1.0 set PS-C_2-slider 0.2 set GCair-slider 0.03 set RQ-slider 1.0 set Vcytox-slider 1.25 set Kcytox-slider 0.5 set O-11-slider 40 set O-12-slider 100 set O-21-slider 20 set O-22-slider 10 set C-11-slider 0 set C-12-slider 0 set C-21-slider 0 set C-22-slider 60 set Cin-slider 105 set stop-timer? true ] if (Scenario = "ARDS") [ set F-slider 1.0 set PS-O_1-slider 0.02 set PS-O_2-slider 0.025 set PS-alv-slider 0.08 set PS-C_1-slider 1.0 set PS-C_2-slider 0.2; 1.0 set GCair-slider 0.03 set RQ-slider 1.0 set Vcytox-slider 1.25; 1.0 set Kcytox-slider 0.5 set O-11-slider 40 set O-12-slider 100 set O-21-slider 20 set O-22-slider 10 set C-11-slider 0 set C-12-slider 0 set C-21-slider 0 set C-22-slider 60 set Cin-slider 105 set stop-timer? true ] if (Scenario = "Hyperoxia") [ set F-slider 1.0 set PS-O_1-slider 0.2 set PS-O_2-slider 0.005 set PS-alv-slider 0.2 set PS-C_1-slider 1.0 set PS-C_2-slider 0.2 set GCair-slider 0.03 set RQ-slider 1.0 set Vcytox-slider 1.25 set Kcytox-slider 0.5 set O-11-slider 40 set O-12-slider 100 set O-21-slider 20 set O-22-slider 10 set C-11-slider 0 set C-12-slider 0 set C-21-slider 0 set C-22-slider 60 set Cin-slider 290 set stop-timer? true ] if (Scenario = "Cyanide-poisoning") [ set F-slider 0.4 set PS-O_1-slider 0.2 set PS-O_2-slider 0.01 set PS-alv-slider 0.2 set PS-C_1-slider 1.0 set PS-C_2-slider 1.0 set GCair-slider 0.03 set RQ-slider 1.0 set Vcytox-slider 0.1 set Kcytox-slider 0.5 set O-11-slider 40 set O-12-slider 100 set O-21-slider 20 set O-22-slider 10 set C-11-slider 0 set C-12-slider 0 set C-21-slider 0 set C-22-slider 60 set Cin-slider 100 set stop-timer? true ] system-dynamics-setup end to go if stop-timer? = true and ticks >= 50000 [stop] ;; setting the condition to stop running ;; the model after 50000 ticks, if respective system-dynamics-do-plot ;; switch is on system-dynamics-go tick end
There is only one version of this model, created over 6 years ago by Victor Iapascurta.
Attached files
File | Type | Description | Last updated | |
---|---|---|---|---|
O2-CO2 Transport and Exchange.png | preview | Preview for 'O2-CO2 Transport and Exchange' | over 6 years ago, by Victor Iapascurta | Download |
This model does not have any ancestors.
This model does not have any descendants.